Reference Guide

Detailed
Description
System setup displays the system boot order. The local video screen may also show additional
information. (IPMI sensor type code 1eh - offset 00h)
Recommended
Response Action
Check system boot settings. Check mass storage controller configuration settings is
applicable.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SEL1301
Message Bootable media found.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SEL1302
Message Non-bootable diskette detected.
Detailed
Description
The disk in the drive is not formatted correctly or does not contain the necessary operating
system files(IPMI sensor type code 1eh - offset 01h)
Recommended
Response Action
Replace diskette with bootable disk.
698