Reference Guide
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID 2475
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
RDU0015
Message The power supplies are not redundant. Insufficient resources to maintain normal operations.
Detailed
Description
The system may power down or operate in a performance degraded state.
Recommended
Response Action
Check the event log for power supply failures. Review system configuration and power
consumption and upgrade or install power supplies accordingly.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message PSUs are not redundant. Insufficient resources. Check PSU cables.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
RDU0017
Message The storage voltage redundancy is lost.
Detailed
Description
The storage system has redundant voltage lines. One of voltage line is no longer available.
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) If the issue still persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health
SubCategory RDU = Redundancy
Severity Severity 2 (Warning)
641