Reference Guide
Recommended
Response Action
Increase power cap.
Category System Health
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 2274
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8558
Message The System Input Power Cap is being enforced with the current Power Supply configuration.
Detailed
Description
The System Input Power Cap is being enforced with the current Power Supply configuration.
Recommended
Response Action
Increase power cap.
Category System Health
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 2274
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8600
Message Bad device plugged into KVM USB port.
Detailed
Description
The device plugged into the KVM USB port is drawing too much current.
Recommended
Response Action
Remove the device from the KVM USB port.
Category System Health
598