Reference Guide
Recommended
Response Action
Remove PSU
Category Audit
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PWR8599
Message Server
arg1
is not compatible with the power supplies in the enclosure.
Arguments
•
arg1 =
server number
Detailed
Description
The Chassis Management Controller cannot turn on the server identified in the message,
because is not compatible with installed PSUs
Recommended
Response Action
Remove Server
Category Audit
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PWR8557
Message The System Input Power Cap is too low to be enforced with the current Power Supply
configuration.
Detailed
Description
The System Input Power Cap is too low to be enforced with the current Power Supply
configuration.
597