Reference Guide
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR8584
Message Chassis Management Controller is unable to turn on server-
arg1
because the power supply
redundancy is lost and Performance Over Power Redundancy feature is disabled and the
power required is less than the available power.
Arguments
•
arg1 =
slot number
Detailed
Description
If power redundancy is lost and the server Performance Over Power Redundancy feature is
disabled, the server turn-on will not be allowed.
Recommended
Response Action
To enable the server to be turned-on, on the Power Configuration page in the Web UI, enable
the server Performance Over Power Redundancy option . Using the RACADM utility, tun the
following command "racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 1". Then retry the oepration.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR8585
Message Chassis Management Controller granted the power required to turn on server-
arg1
.
Arguments
•
arg1 =
slot number
Detailed
Description
Chassis Management Controller granted the power required to turn on the server identified in
the message.