Reference Guide
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8569
Message Unable to power cycle the server
arg1
because the server is off.
Arguments
•
arg1 =
slot number
Detailed
Description
The requested power cycle operation cannot be performed when the server is not turned on.
The server should be already turned on for the power cycle operation to be successful.
Recommended
Response Action
Turn on the server, if necessary, before requesting a power cycle operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8570
Message Unable to communicate to the iDRAC, when trying to power cycle the server
arg1
.
Arguments
•
arg1 =
slot number
Detailed
Description
The Chassis Management Controller is not able to communicate with the iDRAC on the server
identified in the message. Therefore, the server could not be power cycled. This situation may
occur when iDRAC is rebooting.
Recommended
Response Action
Wait for few minutes, and then retry the operation. If the issue persists, do one of the following:
1) Reset the iDRAC, 2) Perform a Virtual Reseat of the server, 3) Remove and re-insert the
server.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
581