Reference Guide
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8562
Message Unable to power on the server
arg1
before power on timer expired.
Arguments
•
arg1 =
server number
Detailed
Description
Unable to power on the server before the power on timer has expired. This happens if the
server did not show power on status change within 30 seconds after the power on operation
was initiated. This issue may also occur when iDRAC is rebooting.
Recommended
Response Action
The Server may need more time to power on. Wait for ten seconds and check the power
status. If the server was not powered on, retry the operation. If the issue persists, remove and
reinsert the server, wait for the iDRAC to complete startup, and retry the operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8563
Message Unable to turn on Server
arg1
due to I/O fabric inconsistency.
Arguments
•
arg1 =
server number
Detailed
Description
The Server identified in the message did not turn on due to a fabric mismatch between the I/O
Module and the Mezzanine card on the Server.
Recommended
Response Action
Make sure that the hardware comtibility between the I/O Module (IOM) and the Mezzanine
(Mezz) card is correct. Check the M1000e Hardware Manual for correct component
compatibility.
577