Reference Guide

arg3 =
priority number
Detailed
Description
This situation occurs if the iDRAC is found to be turned off after power allocation information is
sent by the CMC or if the communications between the CMC and iDRAC is non functional.
Recommended
Response Action
Perform a Virtual Reseat of the component identified in the message. Using the CMC Web UI,
go to Chassis Overview > Troubleshooting > Reset Components, and then select slot for the
component identified in the message and apply the Virtual Reseat.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8555
Message Chassis Management Controller unable to turn on
arg1
-
arg2
at priority
arg3
because of
insufficeint power. Minimum power needed is
arg4
AC Watt, but only
arg5
AC Watt is available.
Arguments
arg1 =
component name
arg2 =
slot number
arg3 =
priority number
arg4 =
min power
arg5 =
avaialble power
Detailed
Description
The request to turn on the component identified in the message was not successful because
insuffficient power is available at the identified priority for the component.
Recommended
Response Action
Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to
Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field view the available power. To add more power, insert more PSUs or remove
unused components from the chassis.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
574