Reference Guide
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8527
Message Server slot power priorities changed - reallocating power.
Detailed
Description
Server slot power priorites were changed. Power to servers is being reallocated.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8528
Message Unable to set Max Power Conservation Mode because the Server Based Power Management
mode is enabled.
Detailed
Description
The Max Power Conservation Mode can be enabled only when Server Based Power
Management Mode is diabled.
Recommended
Response Action
The Max Power Conservation Mode can be changed when Server Based Power Management
mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power >
Configuration page, then uncheck the Enable Server Based Power Management checkbox.
Retry the operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID FALSE
561