Reference Guide

Recommended
Response Action
No response action is required.
Category Audit
SubCategory PSU = Power Supply
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU1000
Message Power supply cable has been removed from
arg1
.
Arguments
arg1 =
PSU Sensor Name
Detailed
Description
The power supply unit is not receiving input AC power. The power cable may not be connected
properly or removed. This can happen if there is an AC failure or problems with the power strip
attached to the enclosure power supply.
Recommended
Response Action
Reconnect the power cable to the power supply unit if it was disconnected. Restore the input
AC power supply. Make sure the power supply is restored to the enclosure from the mains.
Category Storage
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 4234
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PSU1003
Message
arg1
is switched OFF.
Arguments
arg1 =
PSU Sensor Name
518