Reference Guide

Detailed
Description
The operation to read the FRU data from the PSU indentified in the message did not complete
successfully due to internal communication errors.
Recommended
Response Action
Retry the operation. If the condition persists, contact your service provider.
Category Audit
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU8519
Message Enhanced Dynamic Power Supply Engagement (DPSE) is not supported by the current power
supply configuration and is suspended.
Detailed
Description
The Dynamic Power Supply Engagement (DPSE) feature is suspended due to the configuration
or the type of PSU present. The feature is enabled, but suspended until a supported PSU
configuration is in place.
Recommended
Response Action
Dynamic Power Supply Engagement (DPSE) is not supported by the current power supply
configuration. Verify the PSUs are supported. Replace the unsupported PSUs.
Category Audit
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU8520
Message Enhanced Dynamic Power Supply Engagement (DPSE) is fully supported.
Detailed
Description
The Dynamic Power Supply Enagement feature is supported and fully operational.
517