Reference Guide
Detailed
Description
Unable to update the PSU firmware due to PMBus communication errors.
Recommended
Response Action
Retry the firmware update operation. If the problem persists, contact your service provider.
Category Audit
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU8515
Message Unable to set the Enable Dynamic Power Supply Engagement attribute.
Detailed
Description
Unable to set the Enable Dynamic Power Supply Engagement attribute.
Recommended
Response Action
Do the following: 1) Retry the operation. 2) If the issue persists, review the tracelog for more
details. To retrieve the tracelog, in the CMC Web interface, go to Troubleshooting >
Diagnostics page and enter the "gettracelog" command, or use RACADM "gettracelog"
command. If the issue continues to persist, contact your service provider and provide the
tracelog.
Category Audit
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU8516
Message Unable to set redundancy policy because PSU enumeration is in progress.
515