Reference Guide
Trap/EventID FALSE
LCD Message Remote access controller configuration failed. Check screen message
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0195
Message CPU configuration failed.
Detailed
Description
The current processor configuration is unsupported or encountered a fatal exception during
POST. Check the processor configuration. This exception occurred early in system power on,
thus the system may not display video. (BIOS POST exception code C3).
Recommended
Response Action
Review system processor configuration and reduce the system to the minimum configuration.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message CPU configuration failed. Check screen message
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0196
Message Incorrect memory configuration.
Detailed
Description
System BIOS detected an invalid memory population. Reinstall the memory to match the
supported population. This exception occurred early in system power on, thus the system may
not display video. (BIOS POST Exception code C4)
Recommended
Response Action
Re-install memory to match supported memory configuration.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Incorrect memory configuration. Review User Guide