Reference Guide
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR88
Message Power state change failed on
arg1
. (from
arg2
to
arg3
)
Arguments
•
arg1 =
PD Name
•
arg2 =
state
•
arg3 =
state
Detailed
Description
When physical drives in spun down power state are configured, the drives should transition to
spun up power state.. If the drive is not functioning properly, this transition could fail.
Recommended
Response Action
Replace the physical disk and try again. Contact technical support if the issue persists.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR93
Message Microcode update on
arg1
has completed.
Arguments
•
arg1 =
physical disk
Detailed
Description
The physical disk firmware update operation has completed.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
472