Reference Guide
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
MEM8502
Message ECC Memory error rate failover condition detected.
Detailed
Description
An ECC memory condition was detected on the primary CMC and a failover was initiated.
Recommended
Response Action
Reseat the primary CMC and initiate a failover back to the primary CMC. If the problem persists
and multiple failovers occur, contact your service provider. .
Category Audit
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
MEM0000
Message Persistent correctable memory errors detected on a memory device at location(s)
arg1
.
Arguments
•
arg1 =
location
Detailed
Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended
Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory MEM = Memory
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
364