Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
IOV002
Message Unable to create or allocate the required resources.
Detailed
Description
The error occurs because of the following reasons: 1) The chassis manager is unable to
allocate required resources. 2) The chassis manager or chassis infrastructure firmware is
rolled back to an older version. 3) There is an internal communications problem between
chassis components.
Recommended
Response Action
Make sure the firmware for the various chassis components are compatible with each other. If
the firmware has been rolled back to a previous version, this error may occur. If this is the case
power down chassis; issue a racadm wipe command; power up chassis. If not the case power
cycle the chassis. If the problem persists, contact technical suport.
Category Configuration
SubCategory IOV = IO Virtualization
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
IOV003
Message Unable to manage the device located in the PCIe slot specified in the operation.
Detailed
Description
A PCIe device error was detected that does not allow the assignment, unassignment, or the
turning off of the device. The errors can be caused by incorrect PCIe device installation. Only
Dell approved adapters are supported.
Recommended
Response Action
Make sure that supported adapters are used and installed correctly in the PCIe slots.
Category Configuration
SubCategory IOV = IO Virtualization
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None