Reference Guide
Recommended
Response Action
Replace the controller with a supported controller.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL80
Message
arg1
experienced the following warning during startup:
arg2
.
Arguments
•
arg1 =
controller name
•
arg2 =
controller message
Detailed
Description
The controller experienced a problem during statup. The message from the controller is
recorded in the Lifecycle Log.
Recommended
Response Action
For the list of possible remedies for this warning, see Troubleshooting section in the Dell
Shared PowerEdge RAID Controller (SPERC8) documentation.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL81
Message
arg1
has entered safe mode with limited functionality due to
arg2
Arguments
•
arg1 =
Controller name
•
arg2 =
controller message
202