Reference Guide
Detailed
Description
Physical disk(s) have been removed from a virtual disk. The virtual disk will be in Failed state
during the next system reboot. This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
Trap/EventID 4331
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL63
Message Previous configuration was found completely missing during time boot on
arg1
.
Arguments
•
arg1 =
Controller name
Detailed
Description
The controller is unable to retrieve storage configuration saved during last shut down. This can
generally happen if some configured physical disks are removed from the system when the
system was shutdown.
Recommended
Response Action
Shut down the system. Re-insert the removed physical disks and re-start the system.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL64
Message Attempted to import Unsupported Virtual Disk type RAID
arg1
on
arg2
.
193