Reference Guide
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL44
Message Diagnostic message
arg1
from
arg2
Arguments
•
arg1 =
message
•
arg2 =
Controller name
Detailed
Description
A diagnostics test failed. The text for this message is generated by the tool that ran the
diagnostics and can vary depending on the situation.
Recommended
Response Action
Refer to the storage hardware documentation for more information on the diagnostic test.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL45
Message Single-bit ECC error on
arg1
.
Arguments
•
arg1 =
Controller name
Detailed
Description
The Dual In-line Memory Module (DIMM) is beginning to malfunction.
Recommended
Response Action
Replace the Dual In-line Memory Module (DIMM) to avoid data loss or data corruption. The
DIMM is a part of the controller battery pack. Refer to hardware documentation for information
on replacing the DIMM.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
183