Reference Guide
Detailed
Description
An error involving multiple bits has been encountered during a read or write operation. The
error correction algorithm recalculates parity data during read and write operations. If an error
involves only a single bit, it may be possible for the error correction algorithm to correct the
error and maintain parity data. An error involving multiple bits, however, generally indicates
data loss. In some cases, if the multi-bit error occurs during a read operation, then the data on
the disk may be ok. If the multi-bit error occurs during a write operation, then data loss has
occurred.
Recommended
Response Action
Replace the Dual In-line Memory Module (DIMM). The DIMM is a part of the controller battery
pack. Refer to the storage hardware documentation for information on replacing the DIMM.
You may need to restore data from backup.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL41
Message Single-bit ECC error on
arg1
.
Arguments
•
arg1 =
Controller name
Detailed
Description
An error involving a single bit has been encountered during a read or write operation. The error
correction algorithm has corrected this error.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
181