Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0702
Message CPU bus parity error detected.
Detailed
Description
System event log and OS logs may indicate that the exception is external to the processor.
Recommended
Response Action
Check system and operating system logs for exceptions. If no exceptions found, remove input
power, reinstall the processor, then apply input power.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message CPU bus parity error detected. Power cycle system
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0703
Message CPU bus initialization error detected.
Detailed
Description
System event log and OS logs may indicate that the exception is external to the processor.
Recommended
Response Action
1) Check system and operating system logs for exceptions. If no exceptions are found continue.
2) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 3) Make sure the processor is seated correctly. 4) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message CPU bus initialization error detected. Power cycle system
Initial Default. FALSE
154