Reference Guide
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Power input for CPU <number> voltage regulator module is outside of range. Reseat module
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0805
Message The power input for CPU
arg1
voltage regulator module is outside of range, but it is attached to
the system.
Arguments
•
arg1 =
number
Detailed
Description
System performance may be degraded or the system may fail to operate.
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0806
Message CPU
arg1
voltage regulator module is incorrectly configure.
151