Reference Guide

Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8545
Message Detected a missing process failover condition detected. Process =
arg1
.
Arguments
arg1 =
process name
Detailed
Description
A firmware error has occurred causing a CMC failover. The process identified in the message
was not detected. The CMC will restart automatically.
Recommended
Response Action
No response action is required. If multiple failovers occur, contact your service provider.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8546
Message Issues identified witrh Process
arg1
. Failover condition detected
Arguments
arg1 =
process name
Detailed
Description
A firmware error has occurred in the internal firmware process identified in the message. This
condition will cause a CMC failover to occur. If the issue persists, contact your service
provider.
Recommended
Response Action
No response action is required. A failover may result from this condition. If multiple failovers
occur, contact your service provicer.
125