Response Action
Do the following: 1) Remove the server identified in the message. 2) Restart the CMC and wait
for the CMC to complete the start up process. 3) Reinsert the server identified in the message.
If the problem persists, contact your service provider.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID 2545
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8519
Message The LOM riser FRU for slot
arg1
FRU ID
arg2
is not functioning.
Arguments
arg1 =
slot number
arg2 =
fru id
Detailed
Description
FRU of the LOM riser specified in the message is not functioning or CMC is unable to read it.
Recommended
Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID 2545
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8520
Message The FRU on server
arg1
is not functioning.
Arguments
arg1 =
slot number
114