Reference Guide

Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8505
Message Unable to access server:
arg1
because both IPv4 and IPv6 are disabled. NIC Enabled =
arg2
.
Arguments
arg1 =
slot number
arg2 =
state
Detailed
Description
IPv4 and IPv6 are disabled on the specified server and the CMC is unable to display the link to
launch iDRAC web interface.
Recommended
Response Action
Enable IPv4 or IPv6 for the specified server using the CMC command line or CMC Web GUI
interface, so that the link to launch iDRAC is displayed on the CMC Web interface. To enable
the NIC for DHCP using RACADM, enter "racadm setniccfg -m server-<slot number> -d" where
<slot number> is the server identifed in the message. To enable the NIC using the Web
interface, click Server Overview > select the identified server, go to Setup > select the Enable
IPv4 check box and/or the Enable IPv6 check box.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8506
Message A command to shut down the CMC was initiated.
Detailed
Description
A command to shut down the CMC was initiated.
Recommended
Response Action
No response action is required.
Category Audit
107