Reference Guide

Arguments
arg1 =
Bay ID
Detailed
Description
This is an unsupported backplane configuration.
Recommended
Response Action
Review product documentation. Check backplane configuration. If the issue persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory CBL = Cable
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CBL0007
Message Backplane
arg1arg2
cable and backplane
arg3arg4
cable are swapped.
Arguments
arg1 =
Bay ID
arg2 =
Cable Name
arg3 =
Bay ID
arg4 =
Cable Name
Detailed
Description
The Backplane cables need to be connect to the correct Bays
Recommended
Response Action
Check backplane configuration. Re-connect cables to the correct Bay IDs. If the issue persists,
contact technical support. Refer to the product documentation to choose a convenient contact
method.
Category System Health
SubCategory CBL = Cable
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
103