Reference Guide
4 Enabled Not Present
idrac System Disabled
Display the current FlexAddress setting for slot 1.
racadm getflexaddr -i 1
Slot-1 server presence = Present
Slot-1 flexaddress enabled = 1
<
Fabric> <Type> <Server-Assigned> <Chassis-Assigned>
slot1-A1 Gigabit Ethernet 00:1C:
23:CD:AC:D2(active)
00:1E:C9:FF:E3:21
iSCSI 00:1C:
23:CD:AC:D3(active)
00:1E:C9:FF:E3:22
getioinfo
Description Displays general information about the I/O modules on the chassis.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fiber Channel,
and Infiniband.
Synopsis
racadm getioinfo
Example
racadm getioinfo
<IO> <Name> <Type> <Presence> <POST> <Power> <Role>
switch-1 Dell
Ethernet
Passthroug
h
Gigabit
Ethernet
Present OK ON Master
getled
Description Displays the LED settings on a module: blinking, not
blinking, or unknown (for empty slots).
To use this subcommand, you must have the Login User
privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m <
module
> — Specifies the module whose LED settings
you want to view.
<
module
> can be one of the following:
• server-n where n=1–4
• switch-n where n=1
39