Reference Guide

Module ID = Chassis
Severity = Critical
Message = The control panel cable or interconnect is
not connected or is improperly connected.
-----------------------------------------------------------
--------------------
Module ID = PSU-3
Severity = Critical
Message = Power supply 3 failed.
-----------------------------------------------------------
--------------------
Module ID = PSU-4
Severity = Critical
Message = Power supply 4 failed.
-----------------------------------------------------------
--------------------
Module ID = LCD
Severity = Critical
Message = The control panel cable or interconnect is
not connected or is improperly connected.
getassettag
Description Displays the asset tag for the chassis.
To use this subcommand, you must have the CMC Login
User privilege.
Synopsis
racadm getassettag [-m <module>]
Input -m <
module
> — Specifies the module whose asset tag
you want to view.
Legal value: chassis
Example
racadm getassettag -m chassis
racadm getassettag
chassis 78373839–33
getchassisname
Description
Displays the name of the chassis.
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getchassisname
Example
racadm getchassisname
CMC-1
35