User's Manual

36 Carrier Grade Chassis Management Controller User’s Guide Addendum
Table 1-12. Power Budgeting
Item Description
System Input
Max Power
Capacity
Maximum input power that the available power supplies can
supply to the system (in watts).
Input
Redundancy
Reserve
Displays the amount of redundant power (in watts) in reserve that
can be utilized in the event of an input power grid or power supply
unit (PSU) failure. When the chassis is configured to operate in
Grid Redundancy mode, the Input Redundancy Reserve is the
amount of reserve power that can be utilized in the event of an
input power grid failure. When the chassis is configured to
operate in Power Supply Redundancy mode, the Input
Redundancy Reserve is the amount of reserve power that can be
utilized in the event of a PSU failure.
Input Power
Allocated to
Servers
Displays (in watts) the cumulative input power that CMC
allocates to servers based on their configuration.
Input Power
Allocated to
Chassis
Infrastructure
Displays (in watts) the cumulative input power that CMC
allocates to the chassis infrastructure (Fans, IO modules, iKVM,
CMC, Standby CMC and iDRAC on servers).
Input Power
Allocated to
Servers
Displays the total chassis power, in watts, still available for
allocation.
Total Input Power
Available for
Allocation
Displays the total chassis power, in watts, still available for
allocation.
Standby Input
Power Capacity
Displays the amount of standby input power (in watts) that is
available in the event of a Power Supply fault or Power Supply
removal from the system. This field may show a reading when the
system has multiple power supplies and the Dynamic Power
Supply Engagement is enabled.