User's Manual
Carrier Grade Chassis Management Controller User’s Guide Addendum 29
Table 1-7. System Power Status
Item Description
Overall Power Health Indicates the health status of the chassis' power subsystem:
• Green check icon for OK
• Yellow exclamation icon for non-critical
• Red x icon for critical
System Power Status Displays the power status (On, Off, Powering On, Powering
Off) of the chassis.
Redundancy Displays the redundancy status. Valid values are:
• No - PSUs are not redundant.
• Yes - Full redundancy in effect.
Table 1-8. Real-Time Power Statistics
Item Description
System Input Power Displays the current cumulative power consumption of all
modules in the chassis measured from the input side of the
PSUs. The value for system input power is indicated in both
watts and BTU/h units.
Peak System Power Displays the maximum system level input power
consumption since the value was last cleared. This property
allows you to track the maximum power consumption by the
system (chassis and modules) recorded over a period of time.
Click Reset Peak/Min Power Statistics below the table to
clear this value. The value for peak system power is indicated
in both watts and BTU/h units.
Peak System Power
Start Time
Displays the date and time recorded when the peak system
power consumption value was last cleared. The timestamp is
displayed in the format hh:mm:ss MM/DD/YYYY, where hh
is hours (0-24), mm is minutes (00-60), ss is seconds (00-60),
MM is the month (1-12), DD is the day (1-31), and YYYY is
the year. This value is reset with the Reset Peak/Min Power
Statistics button and also when CMC resets or fails over.