User's Manual

28 Carrier Grade Chassis Management Controller User’s Guide Addendum
Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm getpminfo
For more information about getpminfo, including output details, see the
RACADM Command Line Reference Guide for iDRAC7 1.00.00 and CMC 4.1
available on the Dell Support website at support.dell.com/manuals.
Viewing Power Consumption Status
CMC provides the actual input power consumption for the entire system on
the Power Monitoring Status page.
Using the Interface
NOTE: To perform power management actions, you must have Chassis
Configuration Administrator privilege.
To view power consumption status using the Web interface:
1
Log in to the CMC Web interface.
2
Select
Chassis Overview
in the system tree.
3
Click
Power
Power Monitoring
.
The
Power Monitoring
page displays.
NOTE: You can also view the power redundancy status under Power Supplies in
the System tree Status tab.
Table 1-7 through Table 1-10 describe the information displayed on the
Power Monitoring page.
Redundancy Displays the power supply redundancy status.
Values include:
No: Power Supplies are not redundant.
Yes: Full Redundancy in effect.
Table 1-6. System Power Status
(continued)
PSU Configuration Dynamic PSU Engagement