User's Manual
18 Carrier Grade Chassis Management Controller User’s Guide Addendum
• Granted sufficient power for full performance.
• Powered on.
Using Web Interface
To enable Server Performance Over Power Redundancy, perform the following
steps:
1
Click Chassis Overview in the system tree.
2
Click
Power
Configuration
.
3
Select
Server Performance Over Power Redundancy
and click
Apply.
Using RACADM
To enable Server Performance Over Power Redundancy, perform the following
steps:
1
Open a
serial, Telnet, or SSH
text console to CMC and log in.
2
Enable
Server Performance Over Power Redundancy
:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 1
To disable Server Performance Over Power Redundancy, perform the
following steps:
1
Open a
serial, Telnet, or SSH text console
to CMC and log in.
2
Disable
Server Performance Over Power Redundancy
:
r
acadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 0
Remote Logging
Power consumption can be reported to a remote syslog server. Total chassis
power consumption, minimum, maximum, and average power consumption
over a collection period can be logged. For more information on enabling this
feature and configuring the collection/logging interval, see related sections
below.