User's Manual

18 Carrier Grade Chassis Management Controller User’s Guide Addendum
Granted sufficient power for full performance.
Powered on.
Using Web Interface
To enable Server Performance Over Power Redundancy, perform the following
steps:
1
Click Chassis Overview in the system tree.
2
Click
Power
Configuration
.
3
Select
Server Performance Over Power Redundancy
and click
Apply.
Using RACADM
To enable Server Performance Over Power Redundancy, perform the following
steps:
1
Open a
serial, Telnet, or SSH
text console to CMC and log in.
2
Enable
Server Performance Over Power Redundancy
:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 1
To disable Server Performance Over Power Redundancy, perform the
following steps:
1
Open a
serial, Telnet, or SSH text console
to CMC and log in.
2
Disable
Server Performance Over Power Redundancy
:
r
acadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 0
Remote Logging
Power consumption can be reported to a remote syslog server. Total chassis
power consumption, minimum, maximum, and average power consumption
over a collection period can be logged. For more information on enabling this
feature and configuring the collection/logging interval, see related sections
below.