Quick Reference Guide
RACADM Command Line Reference Guide Addendum for Carrier Grade CMC 5
15 SLOT-15 ON 140 W 5
16 SLOT-16 ON 125 W 5 N/A
getsensorinfo
Examples
<racadm getsensorinfo
<senType> <Num> <sensorName> <status> <reading> <units> <lc> <uc>
FanSpeed 1 Fan-1 OK 4908 rpm 2522 14500
FanSpeed 2 Fan-2 OK 4882 rpm 2522 14500
FanSpeed 3 Fan-3 OK 4932 rpm 2522 14500
FanSpeed 4 Fan-4 OK 4930 rpm 2522 14500
FanSpeed 5 Fan-5 OK 4988 rpm 2522 14500
FanSpeed 6 Fan-6 OK 4993 rpm 2522 14500
FanSpeed 7 Fan-7 OK 4923 rpm 2522 14500
FanSpeed 8 Fan-8 OK 4901 rpm 2522 14500
FanSpeed 9 Fan-9 OK 4876 rpm 2522 14500
<senType> <Num> <sensorName> <status> <reading> <units> <lc> <uc>
Temp 1 Ambient_Temp OK 21 celcius N/A 40
<senType> <Num> <sensorName> <status> <AC-OK status>
PWR 1 PS-1 Online OK
PWR 2 PS-2 Online OK
PWR 3 PS-3 Online OK
PWR 4 PS-4 Online OK
PWR 5 PS-5 Online OK
PWR 6 PS-6 Online OK
<senType> <Num> <sensorName> <status>
Cable 1 IO-Cable OK
Cable 2 FPC-Cable OK
Description Displays status for system sensors.
To use this subcommand, you must have CMC Login
User privilege.
Synopsis racadm getsensorinfo