Owner's Manual

If manually updating firmware using Dell Update Packages (DUPs), update the firmware in the following
order:
1. BIOS
2. Lifecycle Controller
3. iDRAC6
NOTE: To update iDRAC firmware to 3.0 or greater from an iDRAC version less than 2.3, you must first
update the iDRAC firmware to version 2.3 before updating to version 3.0 or greater.
Open Issues and Resolutions
Issue 1
Description
Versions 6.0 and 7.0 of Mozilla Firefox Web Browser do not support IPv6 addresses.
Resolution
You must use URLs that contain a registered hostname when accessing a CMC or iDRAC Server that has an
IPv6 address. If the CMC or iDRAC Server also has an IPv4 address, then that is supported.
Versions Affected
CMC version 2.1 or greater
F ixed Issue s/de f
Issue 2
Description
Non-English versions of the Online Help for power configuration pages incorrectly state that the required
privilege for changing power configuration settings is "Chassis Control Administrator".
Resolution
The correct privilege is "Chassis Configuration Administrator".
Limitations
While using the command "racadm config -f" with:
- CMC 3.21 or later versions of the firmware, make sure that the Remote RACADM client version
6.3.0 or later is installed.
- CMC with an earlier version of 3.21 firmware, make sure that the Remote RACADM client
version earlier than 6.3.0 is installed.
The Remote RACADM testfeature command
(racadm -r <IP Address> testfeature ...) does not support the -d (debug) option.
For Single Sign-On and Smart Card login, the client system must be a part of the Active Directory
domain and Kerberos Realm. On Windows 7, clients under the Local Security Policies must make
sure to configure the security option "Network security: Configure encryption types allowed for