Users Guide

Disable inline power on the port extender.
EXEC privilege mode
power inline suspend pe pe-id stack-unit unit-number
pe pe-id — Specify the port extender ID. The range is from 0 to 255.
stack-unit unit-number — Specify the stack unit number of the port extender. The range is
from 0 to 7.
Example of Suspending Power Delivery on the Port Extender
Dell#power inline suspend pe 0 stack-unit 0
Example of Displaying Suspended Power Delivery on the Port Extender
Dell#power inline suspend pe 0 stack-unit 0
Dell#
Dell#show power inline pe 0 stack-unit 0
% Error: Power to StackUnit 0 of PE 0 is in suspended state.
Restoring Power Delivery on the Port Extender
You can temporarily disable and then restore power on the port extender. For information about how to
disable power delivery, see Suspending Power Delivery on the Port Extender.
To restore inline power on the port extender, use the following command. When you restore the inline
power to the port extender, the control bridge (CB) pushes the port extender PoE configurations again to
the port extender.
Restore inline power on the port extender.
EXEC privilege mode
power inline restore pe pe-id stack-unit unit-number
pe pe-id — Specify the port extender ID. The range is from 0 to 255.
stack-unit unit-number — Specify the stack unit number of the port extender. The range is
from 0 to 7.
Example of Restoring Power Delivery on the Port Extender
The following example disable power delivery on the port extender.
Dell#power inline restore pe 0 stack-unit 0
Example of Displaying Restored Power Delivery on the Port Extender
Dell#show power inline pe 0 stack-unit 0
Global inline power Threshold: 99
Power Reserved for inline Power:841W
Total Inline Power Consumed: 0W
Remaining inline power Available:841W
Power Management Mode: Static
Interface Inline Power Inline Power Class Device PoE Port LLDP
Max / Alloc Consumed Type Priority Support
Power over Ethernet (PoE)
825