Reference Guide
• For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet then the slot/port information.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
• For a 40-Gigabit Ethernet interface, enter the keyword
fortyGigE then the slot/port information.
• For a port channel interface, enter the keywords port-
channel
then a number.
• For a VLAN interface, enter the keyword vlan then a
number from 1 to 4094.
vrf vrf-name (OPTIONAL) Enter the keyword vrf followed by the name
of the VRF to display IS-IS traffic interface information
corresponding to that VRF.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Added support for VRF. Introduced on the S6000-ON.
9.5(0.1) Introduced on the Z9500.
9.2(0.2) Introduced on the Z9000.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
Usage Information The following describes the show isis traffic command shown in the
following example.
Item Description
Level-1/Level-2
Hellos (sent/rcvd)
Displays the number of Hello packets sent and received.
PTP Hellos (sent/
rcvd)
Displays the number of point-to-point Hellos sent and
received.
1050
Intermediate System to Intermediate System (IS-IS)