Administrator Guide

show logging driverlog
Display the driver log for the specified hardware component.
C9000 Series
Syntax
show logging driverlog {cp | linecard slot-id | pe pe-id stack—unit unit number
From a PE console, use the show logging driverlog stack—unit unit number to view the driver
logging information for a specified stack-unit.
Parameters
cp Enter the keyword cp to display the driver log for the Control Processor on the switch.
linecard
slot-id
Enter the linecard slot-id parameters to specify the line-card ports for which you
want to display the driver log. The range of line-card slot IDs is from 0 to 11.
pe
pe-id
Enter the keyword pe and the port extender ID to display the driver log information for
the specified port extender. Port extender ID range is from 0 to 255.
stack
unit-number
Enter the keyword stack-unit and the unit number to display the driver log
information for the specified stack-unit. Stack unit range is from 0 to 7.
defaults none
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010 and C1048P.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
Usage Information
This command displays internal software driver information, which may be useful during troubleshooting switch
initialization errors.
Examples
Dell# show logging driverlog cp
0:Task(dlm): [ 6472921]EEPROM LIB ERR: decipherPpId:349 PPID ERROR:
Mismatching VID and MFGID
1:Task(dlm): [ 101]EEPROM LIB ERR: decipherPpId:379 Invalid svcTag(n/a)
2:Task(dlm): [ 93]EEPROM LIB ERR: decipherPpId:390 strtoull
invalidates svcTag(n/a): errno(0), *enr(/)
3:Task(dlm): [ 40]EEPROM LIB ERR: decipherPpId:416 svcTag invalid
changing it to NA
4:Task(chmgr): [ 1555744]EEPROM LIB ERR: decipherPpId:349 PPID ERROR:
Mismatching VID and MFGID
5:Task(chmgr): [ 50]EEPROM LIB ERR: decipherPpId:379 Invalid
svcTag(n/a)
6:Task(chmgr): [ 42]EEPROM LIB ERR: decipherPpId:390 strtoull
invalidates svcTag(n/a): errno(0), *ptr(/)
7:Task(chmgr): [ 39]EEPROM LIB ERR: decipherPpId:416 svcTag invalid
changing it to NA
Dell# show logging driverlog linecard 0