Administrator Guide

SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 0
Status: online
System Mac: f8:b1:56:82:d4:ed
PE Up Time: 22:12:35
PE Description: abc123
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 0/14(A),Te 0/15(A)
Cascade LAG: Po 258(Up), Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
-----------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports Description
-----------------------------------------------------------------------------
0 online - N2048P-PE f8:b1:56:73:87:f9 52 First
1 online - N2048P-PE f4:8e:38:04:f2:67 28 Second
Dell#
Dell#show pe 1 brief
-- Port Extenders Information --
----------------------------------------------------------
PE-id Status Stack-size Type System-MAC
----------------------------------------------------------
1 online 2 N2048P-PE f8:b1:56:73:87:f9
Dell#show pe interface tengigabitethernet 0/22
Port Discovery Status: User Configured Port
PE-id: 1
PE MAC: 6c:c0:00:43:09:90
Dell#show pe interface tengigabitethernet 1/18
Port Discovery Status: User Configured Port
PE-id: 254
PE MAC: 00:00:00:00:00:00
Dell#show pe statistics
PE-ID: 1
PE-CSP Tx Message: 4
PE-CSP Rx Message: 2
ECP Tx: 5
ECP Rx Ack: 5
ECP Dropped: 0
ECP Rx: 3
ECP Tx Ack: 3
PE-ID: 10
PE-CSP Tx Message: 0
PE-CSP Rx Message: 0
ECP Tx: 0
ECP Rx Ack: 0
ECP Dropped: 0
ECP Rx: 0
ECP Tx Ack: 0
1256
Port Extenders (PE)