Users Guide
• %STKUNIT0-M:CP %SWMGR-5-HG-BUNDLE_UNEVEN_DISTRIBUTION: Found uneven distribution in hg-port-channel 0/5/0
• %STKUNIT0-M:CP %SWMGR-5-HG-BUNDLE_UNEVEN_DISTRIBUTION_ALARM_CLEAR: Uneven distribution in hg-port-
channel 0/5/0 got cleared
Guidelines for Monitoring HiGig Link-Bundles
When conguring HiGig link-bundle monitoring on the backplane, follow these guidelines:
• By default, the capability to monitor the trac distribution in a HiGig link bundle on a line-card or SFM NPU is disabled.
• Each line-card NPU uses two HiGig link bundle for its backplane links to connect each SFM (spine) NPU. The convention used to
identify a HiGig link-bundle interface is: hg-port-channel slot/npu-id/0, where slot species the line-card slot number (0–11), npu-id
species the NPU ID number (0), and HiGig port-channel ID which is in the range (0-2) for a line-card NPU
• Each SFM NPU uses a separate HiGig link bundle to connect to each line-card (leaf) NPU. The convention used to identify a HiGig link-
bundle interface is: hg-port-channel slot /higig-port-channel-id, where slot species SFM slot number which is in the range of 0 to 1,
npu-id species the NPU ID number (0)
• HiGig link-bundle monitoring starts only when:
• You enable monitoring for a specied HiGig link bundle using the hg-link-bundle monitor command.
• Bundle usage for egress trac exceeds the threshold congured with the hg-link-bundle monitor trigger-threshold
command.
Alarms are generated only when link-bundle trac levels are high. At low trac levels, only one or two signicant ows may cause
unevenness. However, uneven trac distribution across links during low-trac periods is not critical and does not trigger an alarm.
• You can enable SNMP traps and syslog messages to be generated when an uneven trac distribution is detected in a HiGig link bundle.
• Trac distribution in a HiGig link bundle is calculated as the bandwidth-weighted mean use of all links in the bundle. This calculation is
performed only on links that are up in their operational status.
• The rate interval used to poll trac distribution in member links in a HiGig link bundle is user-congurable. The default polling interval is
15 seconds.
• The trigger threshold species the percentage of total bundle bandwidth used to issue an alarm for uneven trac distribution. The
default is 60 percent. When the mean link utilization is below this value, uneven link-bundle trac is not reported.
The dierence in utilization percentage between the high-used link and low-used link determines the alarm condition. Alarm reporting
for link-bundle monitoring is based on the same algorithm used for LAG/ECMP. An alarm condition occurs when the unevenness in link-
bundle utilization exceeds 10 percent of the congured threshold and remains active until trac on member links falls below the trigger
threshold. If unevenness is recorded for three consecutive measurements, an alarm event is generated. The rate interval denes the
time interval between measurements.
Enabling HiGig Link-Bundle Monitoring
To enable the monitoring of HiGig link bundles, follow these steps.
1 Enable the monitoring of trac distribution on the member links in a HiGig link bundle (port-channel).
CONFIGURATION mode
Dell(conf)#hg-link-bundle-monitor {sfm npu-id hg-port—channel hg-port—channel-id | slot slot
npuUnit npu-id hg-port—channel 0} enable
2 Specify the trigger threshold for HiGig link-bundle monitoring.
CONFIGURATION mode
Dell(conf)#hg-link-bundle-monitor trigger-threshold percentage
Interfaces