Administrator Guide

Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.14(1.5) Added support for UTC time format.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
9.0.0.0 Introduced on the Z9000.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series Original command.
Usage
Information
If you do not specify parameters and enter service timestamps, it appears as service timestamps debug
datetime in the running-configuration.
To view the current options set for the service timestamps command, use the show running-
config command.
From 9.14.1.5 release, the default timestamp display format for the logs is set to local time (service
timestamps log datetime localtime) instead of service timestamps log datetime.
show alarms
View alarms for the system Core, switching core, port modules, fan trays, and power supplies.
C9000 Series
Syntax
show alarms [pe pe-id | threshold] all
Parameters
pe
pe-id
(OPTIONAL) Enter the keyword pe to display the alarms for port extender (PE). The
PE ID range is from 0 to 255.
threshold (OPTIONAL) Enter the keyword threshold to display the temperature thresholds
set for the line cards, RPM, SFMs, and PE (when configured).