Administrator Guide

Table 13. SNMP Trap List (continued)
Message ID Trap Type Trap Option
%TSM-5-SFM_REMOVE: Removed SFM 1
CHM_MAJ_SFM_DOWN ENVMON NONE
%CHMGR-0-MAJOR_SFM: Major alarm: Switch fabric down
CHM_MAJ_SFM_DOWN_CLR ENVMON NONE
%CHMGR-5-MAJOR_SFM_CLR: Major alarm cleared: Switch fabric
up
CHM_MIN_SFM_DOWN ENVMON NONE
%CHMGR-2-MINOR_SFM: MInor alarm: No working standby SFM
CHM_MIN_SFM_DOWN_CLR ENVMON NONE
%CHMGR-5-MINOR_SFM_CLR: Minor alarm cleared: Working
standby SFM present
CHM_PWRSRC_DOWN ENVMON SUPPLY
%CHMGR-2-PEM_PRBLM: Major alarm: problem with power entry
module %s
CHM_PWRSRC_CLR ENVMON SUPPLY
%CHMGR-5-PEM_OK: Major alarm cleared: power entry module %s
is good
CHM_MAJ_ALARM_PS ENVMON SUPPLY
%CHMGR-0-MAJOR_PS: Major alarm: insufficient power %s
CHM_MAJ_ALARM_PS_CLR ENVMON SUPPLY
%CHMGR-5-MAJOR_PS_CLR: major alarm cleared: sufficient
power
CHM_MIN_ALARM_PS ENVMON SUPPLY
%CHMGR-1-MINOR_PS: Minor alarm: power supply non-redundant
CHM_MIN_ALARM_PS_CLR ENVMON SUPPLY
%CHMGR-5-MINOR_PS_CLR: Minor alarm cleared: power supply
redundant
CHM_MIN_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MINOR_TEMP: Minor alarm: chassis temperature
CHM_MIN_ALRM_TEMP_CLR ENVMON TEMP
%CHMRG-5-MINOR_TEMP_CLR: Minor alarm cleared: chassis
temperature normal (%s %d temperature is within threshold
of %dC)
CHM_MAJ_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MAJOR_TEMP: Major alarm: chassis temperature high
(%s temperature reaches or exceeds threshold of %dC)
CHM_MAJ_ALRM_TEMP_CLR ENVMON TEMP
%CHMGR-2-MAJOR_TEMP_CLR: Major alarm cleared: chassis
temperature lower (%s %d temperature is within threshold of
%dC)
CHM_FANTRAY_BAD ENVMON FAN
1660 SNMP Traps