Administrator Guide
show interfaces transceiver
Display the physical status and operational status of an installed transceiver. The output also displays the transceiver’s serial number.
C9000 Series
Syntax
show interfaces [tengigabitethernet slot/port | fortyGigE slot/port | peGigE
pe-id/stack-unit/port | peTenGigE pe-id/stack-unit/port] transceiver
Parameters
tengigabitetherne
t
For a 10G interface, enter the keyword tengigabitethernet then the slot/port
(ports or port range) information.
fortyGigE For a 40G interface, enter the keyword fortyGigE then the slot/port (ports or port-
range)information.
peGigE For a port extender Gigabit Ethernet interface, enter the keyword peGigE then the pe-
id / stack-unit / port-id information. The pe-id range is from 0 to 255; the stack-unit unit-
number range is from 0 to 7; and the port-id range is from 1 to 48.
NOTE: The peGigE or peTenGigE option is only visible when the feature
extended bridge feature is enabled.
peTenGigE For a port extender 10-Gigabit Ethernet interface, enter the keyword peTenGigE then
the pe-id / stack-unit / port-id information. The pe-id range is from 0 to 255; the stack-
unit unit-number range is from 0 to 7; and the port-id range is 25 to 28 or 49 to 52
depending on the PE.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.13.0.1P1 Introduced peTenGigE interface support on the C9010.
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.1.1.0 Introduced on the E-Series ExaScale.
7.8.1.0 Output augmented with diagnostic data for pluggable media.
7.7.1.0 Removed three fields in the output: Vendor Name, Vendor OUI, and Vendor PN.
7.6.1.0 Introduced on the C-Series and S-Series.
6.5.4.0 Introduced on the E-Series.
Usage Information The following describes the show interfaces transceiver command shown in the following example.
Line Description
Rx Power
measurement type
Output depends on the vendor, typically either “Average” or “OMA” (Receiver optical
modulation amplitude).
Temp High Alarm
threshold
Factory-defined setting, typically in Centigrade. Value differs between SFPs and SFP+.
Interfaces 741