Administrator Guide

static Enter the keyword static to configure the static mode for the specified port extender.
Defaults Static
Command Modes
CONFIGURATION
CONFIGURATION TERMINAL BATCH
Command History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.10(0.0) Introduced the Configuration Terminal Batch mode on C9010.
9.9(0.0) Introduced on the C9010.
Usage Information
The power inline mode command allows you to manage inline power supply on the port extender (PE)
ports. You can configure class or static mode to manage inline power in a port extender.
When class mode is configured, maximum power for the particular class of device is allocated. Class mode
supports power allocation via Layer 2 classification and power negotiation by Link Layer Discovery Protocol
(LLDP) 802.3at standard . When static mode is configured, the inline power is allocated based on the actual
power consumption by the powered device. Power negotiation via LLDP is not supported in static mode.
Use this command in Configuration Terminal Batch mode to manage inline power supply in a dual-homing setup.
The following examples show power management mode, “class” configured for the port extender 255.
Example
Dell(conf)#power inline mode pe 0 stack-unit 0 static
Dell#show power inline pe 0 stack-unit 0
Global inline power Threshold : 99
Power Reserved for inline Power: 841W
Total Inline Power Consumed: 0W
Remaining inline power Available: 841W
Power Management Mode: Static
Interface Inline Power Inline Power Class Device PoE Port
LLDP
Max / Alloc Consumed Type Priority
Support
(Watts) (Watts)
------------- ------------ ------------ ------- ------ --------
------
PeGi 0/0/0 30.00/0.00 0.00 NO_PD -
low 0
power inline restore pe
Enable the temporarily suspended PoE power supply to all the ports in a port extender unit.
C9000 Series
Syntax
power inline restore pe pe-id stack-unit unit number
Parameters
pe
pe-id
Enter the keyword pe and the port extender ID. Range is from 0 to 255.
stack-unit
unit
number
Enter the keyword stack-unit and the stack-unit number. Range is from 0 to 7.
1328 Port Extenders (PE)