Users Guide

PE Configuration: Local Status: Present, Remote Status: Present
------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
------------------------------------------------------------------------
1 online - C1048P f8:b1:56:6e:20:07 52
Dell#
On the VLT peer:
Dell#show pe 1
Codes: A - Active, I - Inactive
Reason: CTM - Card Type Mismatch, CAM - CAM ACL Mismatch
SVM - Software Version Mismatch, UE - Unknown Error
Offline Reason: UNP - Unit Not Present,
ICE - IPC CP Error, IRE - IPC RP Error
ISE - IPC Setup Error, CVE - Card Validation Error
PE-ID assigned: 1
Status: online
System Mac: f8:b1:56:6e:20:07
PE Up Time: 00:17:15
PE Discovery Status: Provisioned PE
User Configured Cascade Ports: Te 1/4(A)
Cascade LAG: Po 258, Local Status: Up, Remote Status: Up
PE Configuration: Local Status: Present, Remote Status: Present
------------------------------------------------------------------------
Stack-id Status Reason Type UnitMac No. of Ports
------------------------------------------------------------------------
1 online - C1048P f8:b1:56:6e:20:07 52
Standalone System
You can connect a standalone system to a system that already has a PE to make it dual homed. In the following illustration, PE
1 is connected to System A and System B is a standalone.
Figure 108. Standalone System and System with PE — Before setting up Dual Homing
To convert the above system into a dual homing setup, perform the following:
1 Repeat the steps 1 to 6 from Systems with Port Extender.
2 Change the uplink port connections of the PE, so that the uplink ports are connected to each of the VLT peers. In the
above example, the link connected to Te 0/1 in System A is disconnected and connected to Te 1/4 in System B.
Port Extenders (PEs) 699