Users Guide

Defaults Not configured.
Command Modes CONFIGURATION-MAC ACCESS LIST-EXTENDED
Command
History
This guide is platform-specific. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
7.4.1.0 Added the monitor option.
6.1.1.0 Introduced on the E-Series.
Usage
Information
When you use the log option, the CP processor logs detail the packets that match. Depending on how
many packets match the log entry and at what rate, the CP may become busy as it has to log these
packet details.
By default, 10 ACL logs are generated if you do not specify the threshold explicitly. The default frequency
at which ACL logs are generated is five minutes. By default, flow-based monitoring is not enabled.
Use the monitor option only when you are using flow-based monitoring. For more information, refer to
the Port Monitoring chapter in the C9000 Series Configuration Guide.
NOTE: When ACL logging and byte counters are configured simultaneously, byte counters may
display an incorrect value. Configure packet counters with logging instead.
Related
Commands
deny configures a MAC ACL filter to drop packets.
seq configure a MAC ACL filter with a specified sequence number.
seq
Configure a filter with a specific sequence number.
C9000 Series
Syntax
seq sequence-number {deny | permit} {any | host mac-address | mac-source-
address mac-source-address-mask} {any | host mac-address | mac-destination-
address mac-destination-address-mask} [ethertype operator] [count [byte]]
[log [interval minutes] [threshold-in-msgs [count]] [monitor]
To delete a filter, use the no seq sequence-number command.
Parameters
sequence-
number
Enter a number as the filter sequence number. The range is from zero (0) to
65535.
deny Enter the keyword deny to drop any traffic matching this filter.
permit Enter the keyword permit to forward any traffic matching this filter.
any Enter the keyword any to filter all packets.
266 Access Control Lists (ACL)