Installation manual

Installing RPMs and Line Cards | 19
5
Installing RPMs and Line Cards
The C300 System accommodates eight line cards and two RPMs.
Route Processor Modules
The C300 system requires the installation of at least one Route Processor Module (RPM); two are
recommended.
One RPM provides 48 Gigabits of bandwidth to each line card.
Two RPMs provides 96 Gigabits of bandwidth to each line card.
RPMs are designed to be installed in either the R0 or R1 slot (see
Figure 2-1
). Do not force RPMs into
line cards slots. RPMs are keyed differently than line cards to prevent improper installation.
NOTE: If your system contains two RPMs, both RPMs must contain the same software image.
RPM Label and LEDs
Table 5-1
describes the RPM LED states and the RPM front panel.
Table 5-1. RPM Front Panel and LED Descriptions
Section Label Description
Management Console Port Use this RJ-45 jack for the initial system boot, as well as system configuration and
monitoring. Modem connection is not supported on the Console.
10/100/1000
Ethernet
Use this non-routable Ethernet port to download images and manage the system. FTP and
Telnet operations are supported. This port is an RJ-45.
Port LEDs:
L/A:
Blinking Amber: 100M speed
Solid Amber: 1G speed
Off: 10M speed
Speed:
Blinking Green: Link detected/ Activity
Solid Green: Link detected/ No Activity
Off: No Link/ Card Offline
Alarm LED Red: Major Alarm—a critical condition exists (such as a severe over temperature condition).
See
Alarms
for more information.
Flashing red: Minor Alarm—a serious condition exists (such as a single fan failure or a line
card failure). See
Alarms
for more information.
Unlit: no alarm conditions.