Deployment Guide

60 | File Management
www.dell.com | support.dell.com
Defaults
None.
Command Mode
EXEC Privilege
Command
History
Example
Command example: restore fpga-image
Usage
Information
Reset the card using the power-cycle option after restoring the FPGA command.
Related
Commands
upgrade fpga-image
c
Upgrade the primary FPGA image.
Syntax
upgrade fpga-image {rpm {number | all}| linecard {number | all} [system-fpga | link-fpga]
| all} {booted | file-url}
Parameters
Version 7.7.1.0
Renamed keyword
primary-fpga-flash to fpga-image.
Version 7.5.1.0 Introduced on C-Series
FTOS# restore fpga-image linecard 6
Current FPGA information in the system:
=======================================
Card FPGA Name Current Version New Version
------------------------------------------------------------------------
LC6 48 Port 1G LCM POEPLUS FPGA A: 0.1 restore
***********************************************************************
* Warning - Upgrading FPGA is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Please do not reset/powercyle or reload. *
* Proceed with caution ! *
***********************************************************************
Restore fpga image for linecard 6 [yes/no]: y
FPGA restore in progress. Please do NOT power off the card.
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result :
================
Linecard 6 FPGA restore successful.
FTOS#
reset Reset a card.
rpm number Enter rpm followed by the RPM slot number to upgrade an RPM FPGA
Range: 0-1
linecard number Enter linecard followed by the line card slot number to upgrade a
linecard FPGA.
Range: 0-7 on the C7008/C300, 0-3 on the C7004/C150