Command Line Reference Guide
Interfaces | 629
Figure 23-46. show interfaces port-channel brief Command Example
MTU 1554... Displays link and IP MTU.
LineSpeed Displays the interface’s line speed. For a port channel interface, it is the
line speed of the interfaces in the port channel.
Members in this... Displays the interfaces belonging to this port channel.
ARP type:... Displays the ARP type and the ARP timeout value for the interface.
Last clearing...
Displays the time when the
show interfaces counters were cleared.
Queueing strategy. States the packet queuing strategy. FIFO means first in first out.
packets input... Displays the number of packets and bytes into the interface.
Input 0 IP packets... Displays the number of packets with IP headers, VLAN tagged headers
and MPLS headers.
The number of packets may not add correctly because a VLAN tagged IP
packet counts as both a VLAN packet and an IP packet.
0 64-byte... Displays the size of packets and the number of those packets entering that
interface. This information is displayed over two lines.
Received 0... Displays the type and number of errors or other specific packets received.
This information is displayed over three lines.
Output 0... Displays the type and number of packets sent out the interface. This
information is displayed over three lines.
Rate information... Displays the traffic rate information into and out of the interface. Traffic
rate is displayed in bits and packets per second.
Time since... Displays the time since the last change in the configuration of this
interface.
Table 23-13. show interfaces port-channel brief Command Example Fields
Field Description
LAG Lists the port channel number.
Mode Lists the mode:
• L3 - for Layer 3
• L2 - for Layer 2
Status Displays the status of the port channel.
• down - if the port channel is disabled (shutdown)
• up - if the port channel is enabled (no shutdown)
Uptime Displays the age of the port channel in hours:minutes:seconds.
Table 23-12. show interfaces port-channel Command Example Fields (continued)
Field Description
FTOS#sh int por 1 br
LAG Mode Status Uptime Ports
1 L2 up 00:00:08 Gi 3/0 (Up) *
Gi 3/1 (Down)
Gi 3/2 (Up)
FTOS#