Command Line Reference Guide

1148 | Power over Ethernet (PoE) and Power over Ethernet Plus (PoE+)
www.dell.com | support.dell.com
show power detail
c s
Display the total power consumption and power consumption by component.
Syntax
show power detail
Command Modes
EXEC
EXEC Privilege
Command
History
Example
FTOS# show power detail
Catalog slot Logic Power Inline Power Inline Power
Name Id Consumed Allocated Consumed
(Watts) (Watts) (Watts)
---------------------------------------------------------------------------
E48IB 0 100 0.00 0.00
E48IB 1 100 0.00 0.00
EX8PB 2 120 0.00 0.00
E48TB 3 100 0.00 0.00
RPM 0 100 - -
RPM 1 100 - -
E48PB 4 130 0.00 0.00
E48VB 5 100 0.00 0.00
E48IB 6 100 0.00 0.00
E48VB 7 100 0.00 0.00
CC-C300-FAN - 85 - -
Total Inline Power Available: 0.00 W
Total Inline Power Allocated: 0.00 W
Total Inline Power Consumed : 0.00 W
Total Inline Power Remaining: 0.00 W
Version 8.4.1.0 Inline Power Used removed from the output.
Version 7.7.1.0 Introduced on the S-Series.
Version 4.2.1.0 Introduced on the C-Series.
Table 43-1. show power detail Command Output Fields
Unit (S-Series only) The stack member unit ID.
Catalog Name (C-Series only) Displays the component’s Dell Networking catalog number.
Slot ID (C-Series only) Displays the slot number in which the line card or RPM is
installed.
Total Power Available (S-Series only) The total power available in the stack member or chassis.
Note: On the S-Series a maximum of 790W can be allocated for PoE,
even if you add the 470W external power supply.
Note: This field is not shown on the C-Series. The total power available
will vary, depending upon the type and number of PSUs installed.
Logic Power Consumed The power consumed by the system logic.
Inline Power Available Power available for PoE for the S-Series (whatever was configured using the
power-budget command. Default: 320 watts
There is no default value for the C-Series, as power will vary, depending upon
type and number of PSUs installed.
Inline Power Allocated Total power allocated to the ports.
Inline Power Consumed Total power consumed by connected devices.
Inline Power Remaining Difference between power available and power allocated.