Reference Guide

Table Of Contents
792 | Power over Ethernet
www.dell.com | support.dell.com
Enabling PoE on more ports than is supported by the power budget produces one of these results:
If the newly PoE-enabled port has a lower priority, then the command is accepted, but power is not
allocated to the port. In this case, the following message is displayed.
If the newly PoE-enabled port has a higher priority, then the CLI is accepted, and power is terminated
on the lowest priority port in the chassis. If another power supply is added to the system at a later time,
both ports receive power.
If all of the lower priority ports combined cannot meet the power requirements of the newly enabled
port, then the CLI is accepted, but power on the lower priority ports is not terminated, and no power is
supplied to the port.
The second result in this scenario is true even if a powered device is not connected to the port. Power can
be allocated to a port, thus subtracting it from the power budget and making it unavailable to other ports,
but that power does not have to be consumed.
Manage Power Priorities
PoE-enabled ports have power access priorities based first on their configuration and then by line card and
port number. The default prioritization is presented in Table 36-5.
You can augment the default prioritization using the command
[no] power inline priority {critical | high |
low}, where critical is the highest priority, and low is the lowest. FTOS ignores any LLDP-MED priority on
this port if you configure a priority with this command. If you do not configure a port priority with this
command, FTOS honors any LLDP-MED priority.
Message 1 Insufficient Power to Enable PoE
%Warning: Insufficient power to enable. POE oper-status set to OFF for port <linecard/
portnumber>
Note: For S-Series, where Table 36-5 refers to “line cards with the lowest slot number”, substitute
“S-Series stack members with the lowest unit ID”.)
Table 36-5. PoE Ports Priorities
Configuration Port Number Priority
Ports configured with
power inline static Ports with the lowest port numbers in line cards with the lowest
slot number
1
Ports with the lowest port numbers 2
Ports configured with
power inline auto Ports with the lowest port numbers in line cards with the lowest
slot number
3
Ports with the lowest port numbers 4